Aircon fault code lookup.
Search or filter by brand to decode what a flashing error on your split, ducted or multi-head aircon actually means. Each entry lists the likely cause and the first thing to check before booking a service call. Covers every major brand we install plus the ones we don’t.
| Brand | System | Code | Likely meaning | First check |
|---|---|---|---|---|
| Mitsubishi Electric | Air conditioner | P1 | Indoor room-thermistor fault | Indoor unit thermistor loose or failed, needs a service call. |
| Mitsubishi Electric | Air conditioner | P2 | Indoor pipe-thermistor fault | Pipe sensor open-circuit, usually a swap-out fix. |
| Mitsubishi Electric | Air conditioner | P4 | Drain sensor fault | Check the condensate drain pan isn't clogged; sensor may need replacing. |
| Mitsubishi Electric | Air conditioner | P5 | Drain pump fault | Condensate pump seized or blocked, clear the drain line and re-test. |
| Mitsubishi Electric | Air conditioner | P6 | Coil frost / overheat protection | Filter blocked or airflow restricted. Clean filters + check outdoor coil. |
| Mitsubishi Electric | Air conditioner | P8 | Pipe temperature abnormal | Low refrigerant charge or restriction. Needs an ARC-licensed tech. |
| Mitsubishi Electric | Air conditioner | E0 | Remote-control transmission error | Wired controller comms drop, check controller wire terminations. |
| Mitsubishi Electric | Air conditioner | E6 | Indoor / outdoor comms failure | Check the S1-S2-S3 comms wire between indoor & outdoor units. |
| Mitsubishi Electric | Air conditioner | E9 | Indoor / outdoor comms error (variant) | Same as E6, comms cable, check for damage or loose terminals. |
| Mitsubishi Electric | Air conditioner | U2 | Compressor overheat / oil shortage | STOP using the unit. Compressor at risk, book a warranty service call. |
| Mitsubishi Electric | Air conditioner | U4 | Outdoor thermistor open-circuit | Outdoor coil or discharge sensor faulty. Tech required. |
| Daikin | Air conditioner | A1 | Indoor PCB defect | Indoor board fault, power-cycle the unit first, then service if it returns. |
| Daikin | Air conditioner | A5 | High-pressure control / freeze-up protection | Filter dirty or outdoor coil blocked. Clean both, re-test. |
| Daikin | Air conditioner | A6 | Indoor fan motor fault | Fan motor stalled or capacitor failed. Service call. |
| Daikin | Air conditioner | C4 | Indoor heat-exchanger thermistor fault | Sensor open-circuit, swap-out fix. |
| Daikin | Air conditioner | C9 | Indoor air suction thermistor fault | Room-temp sensor failed. Service call. |
| Daikin | Air conditioner | E1 | Outdoor PCB defect | Outdoor board fault. Power-cycle first, then book service. |
| Daikin | Air conditioner | E5 | OL activated (compressor overload) | STOP unit. Compressor overload, likely refrigerant charge or fan issue. |
| Daikin | Air conditioner | E6 | Compressor lock / start failure | STOP unit. Compressor won't spin up. Warranty / service. |
| Daikin | Air conditioner | E7 | Outdoor fan motor lock | Check for debris jamming the outdoor fan. If clear, motor swap. |
| Daikin | Air conditioner | F3 | Discharge-pipe temperature too high | Low refrigerant charge or blocked outdoor coil. ARC tech needed. |
| Daikin | Air conditioner | L5 | Inverter compressor abnormal | STOP unit. Inverter fault, warranty repair. |
| Daikin | Air conditioner | U0 | Refrigerant shortage | Refrigerant low, check for leak, book an ARC-licensed tech. |
| Daikin | Air conditioner | U4 | Indoor / outdoor comms error | Check the F1-F2 comms wire, loose terminal or damaged cable. |
| Fujitsu | Air conditioner | E:EE | Room-temp thermistor fault | Thermistor open, sensor swap. |
| Fujitsu | Air conditioner | E:11 | Comms error indoor ↔ outdoor | Comms wire fault. Check terminals both ends. |
| Fujitsu | Air conditioner | E:12 | Outdoor comms not responding | Outdoor board or power supply, book service. |
| Fujitsu | Air conditioner | E:14 | Signal transmission error (wired remote) | Wired controller, check the H1-H2 line terminations. |
| Fujitsu | Air conditioner | OP:00 | Outdoor high-pressure protection | Airflow blocked at outdoor unit. Clear obstructions and re-test. |
| Fujitsu | Air conditioner | OP:04 | Compressor discharge-temp protection | STOP unit. Likely low charge or blocked coil. |
| Panasonic | Air conditioner | H11 | Indoor / outdoor comms failure | Comms cable fault. Check terminals. |
| Panasonic | Air conditioner | H15 | Compressor sensor error | Sensor failed, service call. |
| Panasonic | Air conditioner | H27 | Outdoor air sensor error | Sensor open, swap-out fix. |
| Panasonic | Air conditioner | F91 | Refrigerant abnormal (leak) | STOP unit. Refrigerant leak, ARC tech needed. |
| Panasonic | Air conditioner | F99 | Outdoor DC over-current | STOP unit. Inverter / compressor fault. Warranty service. |
| LG | Air conditioner | CH01 | Indoor room-thermistor error | Sensor open, swap fix. |
| LG | Air conditioner | CH02 | Indoor pipe sensor error | Sensor open, swap fix. |
| LG | Air conditioner | CH05 | Indoor / outdoor comms error | Comms cable, check terminals both ends. |
| LG | Air conditioner | CH21 | IPM fault (inverter power module) | STOP unit. Inverter power stage, book warranty service. |
| Kaden | Air conditioner | E1 | Indoor & outdoor comms error | Check comms cable connection between heads. |
| Kaden | Air conditioner | E2 | Room temp sensor fault | Sensor open, sensor swap by installer. |
| Kaden | Air conditioner | E5 | Overcurrent protection | Airflow blocked or refrigerant charge low. Service call. |
| Kaden | Air conditioner | F1 | Outdoor unit sensor fault | Outdoor sensor swap, book service. |
| Kaden | Air conditioner | F3 | Compressor discharge temp too high | STOP unit. Likely low charge. ARC tech required. |
| Brivis | Gas heater | h01 30 | Fan limp mode, fan speed sensor signal invalid | Unit runs at safe speed. Book gas heater service, main fan sensor or motor. |
| Brivis | Gas heater | h01 31 | Flame roll-out during ignition (auto restart) | Unit will attempt to restart. If it persists, book service, roll-out sensor / burner alignment. |
| Brivis | Gas heater | h01 32 | Data error, parameters reset to default | Controller memory fault. Book service to re-commission the unit. |
| Brivis | Gas heater | h01 33 | Modulating gas valve, open circuit on coil | Modulation coil fault. Needs a gas fitter service call. |
| Brivis | Gas heater | h01 35 | Supply-air thermistor fault (open / short) | Sensor swap by installer, no heat until fixed. |
| Brivis | Gas heater | h01 36 | Bad supply-air thermistor location | Thermistor not reaching setpoint in time, indicates blocked ducts or sensor moved. Book service. |
| Brivis | Gas heater | h01 37 | Speed sensor error, unit in safe mode | Main-fan speed signal wrong. May lockout if persistent. Book service. |
| Brivis | Gas heater | h01 40 | Return-air overheat, flue-fan overheat switch open | Return-air blockage or fan issue. Clean return-air filter first, then service. |
| Brivis | Gas heater | h01 41 | Supply-air overheat switch tripped | Blocked supply ducts / grille. Check no vents shut. Service if it persists. |
| Brivis | Gas heater | h01 42 | Supply-air thermistor temp exceeded overheat threshold | Duct blockage forcing overheat. Open all vents, clean filter, book service if persists. |
| Brivis | Gas heater | h01 43 | Overheat cool-down in progress | Unit cooling itself down safely. Wait 5 min. If it recurs, service. |
| Brivis | Gas heater | h01 44 | Flame roll-out detected during ignition | Roll-out sensor triggered. Book gas fitter, burner or heat exchanger issue. |
| Brivis | Gas heater | h01 45 | Low 24V AC supply voltage | Power supply issue on the low-voltage transformer. Service call. |
| Brivis | Gas heater | h01 46 | No flame on ignition attempt | Check gas isolation valve is on. If good, book a gas fitter, igniter, gas pressure, or flame rod. |
| Brivis | Gas heater | h01 47 | Unstable flame, dropped during validation | Gas pressure or flame rod issue. Book a gas fitter. |
| Brivis | Gas heater | h01 48 | Pressure loss, combustion chamber switch opened mid-cycle | Flue restriction or fan issue. Book service, check flue is clear. |
| Brivis | Gas heater | h01 49 | Flame lost during heating cycle | Gas supply interruption or flame sensor issue. Book gas fitter. |
| Brivis | Gas heater | h01 50 | Ignition lockout, max ignition attempts exceeded | STOP unit. Power cycle at the wall control to reset. If it re-locks, gas fitter required. |
| Brivis | Gas heater | h01 51 | Roll-out signal with no gas active (sensing circuit fault) | Roll-out sensor circuit fault. Book service. |
| Brivis | Gas heater | h01 52 | Flame signal detected with no gas, flame sensing circuit fault | Flame rod / control board fault. Book service. |
| Brivis | Gas heater | h01 53 | Overheat lockout | STOP unit. Overheat safety triggered multiple times. Gas fitter required before use. |
| Brivis | Gas heater | h01 54 | Roll-out lockout, max roll-out events during heat cycle | STOP unit. Repeated roll-out, burner / heat exchanger inspection required. |
| Brivis | Gas heater | h01 55 | Flame validation lockout, flame lost repeatedly at validate step | STOP unit. Book gas fitter, flame or gas supply issue. |
| Brivis | Gas heater | h01 56 | Pressure switch stuck open, flue fan on but no pressure | Pressure switch or tube blocked. Book service. |
| Brivis | Gas heater | h01 57 | Pressure switch stuck closed, flue fan off but pressure detected | Pressure switch stuck. Book service. |
| Brivis | Gas heater | h01 58 | Pressure switch fail, max pressure-loss events exceeded | STOP unit. Flue / pressure switch fault. Book service. |
| Brivis | Gas heater | h01 59 | Cross-check comms error between primary and secondary MCU | Control board comms fault. Board-level service required. |
| Brivis | Gas heater | h01 60 | Motor open circuit, no zero-cross detect signal | Fan motor open circuit, book service. Motor swap likely. |
| Brivis | Gas heater | h01 61 | Primary valve stuck off, relay contact not closing | Gas valve relay fault. Book gas fitter. |
| Brivis | Gas heater | h01 62 | Primary valve stuck on, relay contact welded | STOP unit. Gas valve relay stuck. Gas fitter needed immediately. |
| Brivis | Gas heater | h01 63 | Primary valve fail, relay not closing during heating | STOP unit. Gas valve fault. Book gas fitter. |
| Brivis | Gas heater | h01 64 | Modulating valve overcurrent (>150 mA) | Modulation coil short. Book service. |
| Brivis | Gas heater | h01 65 | Motor lockout, fan limp + open circuit or overheat combo | STOP unit. Multiple fan faults combined. Book service. |
| Brivis | Gas heater | h01 66 | Secondary valve stuck off | Second gas valve relay fault. Gas fitter. |
| Brivis | Gas heater | h01 67 | Secondary valve stuck on | STOP unit. Gas valve stuck. Gas fitter needed immediately. |
| Brivis | Gas heater | h01 68 | Secondary valve fail during heating | STOP unit. Gas fitter required. |
| Brivis | Gas heater | h01 69 | Fuse blown, 24V AC voltage lost | 2A fuse on the control board is open. Service call to replace + diagnose why it blew. |
| Brivis | Gas heater | h01 70 | Remote MCU shutdown fail | Control-board fault. Board-level service. |
| Brivis | Gas heater | h01 71 | Remote MCU state mismatch | Control-board fault. Board-level service. |
| Brivis | Gas heater | h01 72 | Ambiguous fault, unattributed shutdown | Undiagnosed shutdown. Book service to read secondary log. |
| Brivis | Gas heater | h01 73 | Remote MCU next-state mismatch | Control-board firmware or hardware fault. Book service. |
| Brivis | Gas heater | h01 74 | Remote MCU lockout (secondary board locked) | STOP unit. Board-level service required. |
| Brivis | Gas heater | h01 75 | AC input scan fault, 24V input stuck high | Input scanning circuit fault. Board-level service. |
| Brivis | Gas heater | h01 76 | Lockout storage fault, non-volatile memory access failure | Control board's ability to store lockouts compromised. Book service. |
| Brivis | Gas heater | h01 77 | Remote MCU IO mismatch | IO state mismatch between board MCUs. Book service. |
| Brivis | Gas heater | h01 79 | A/D converter reference voltage check failed | Board-level analog fault. Service. |
| Brivis | Gas heater | h01 80 | Flame sense fault, measured voltage out of range | Flame rod or sensing circuit fault. Book gas fitter. |
| Brivis | Gas heater | h01 81 | Roll-out sense fault, sensor voltage out of range | Roll-out sensor circuit fault. Book service. |
| Brivis | Gas heater | h01 82 | System timing fault, MCU timing vs 50 Hz mismatch | Control-board timing fault. Board-level service. |
| Brivis | Gas heater | h01 83 | System execution fault, internal MCU error | Control-board firmware fault. Board-level service. |
| Brivis | Gas heater | h01 84 | Control board lockout (system lockout initiated) | STOP unit. Board-level service required. |
| Brivis | Gas heater | h01 85 | Control board lockout (system lockout initiated) | STOP unit. Board-level service required. |
| Brivis | Gas heater | h01 86 | Control board lockout (system lockout initiated) | STOP unit. Board-level service required. |
| Brivis | Gas heater | h01 87 | Cross-check comms fault, no MCU comms >10 s | Control-board comms failure. Board-level service. |
| Brivis | Gas heater | h01 88 | Control board lockout (system lockout initiated) | STOP unit. Board-level service required. |
| Brivis | Gas heater | h01 89 | MCU non-volatile storage test code (not seen in normal use) | Diagnostic-only code, service tech will interpret. If it appears on normal operation, book service. |
| Reclaim | Hot water | E1 | Ambient temp sensor fault | Outdoor sensor open-circuit. Book a Reclaim-accredited service tech. |
| Reclaim | Hot water | E2 | Evaporator temp sensor fault | Evaporator sensor fault, swap-out fix by a tech. |
| Reclaim | Hot water | E3 | Discharge / suction sensor fault | Sensor swap by an ARC-licensed tech. |
| Reclaim | Hot water | E4 | Tank temp sensor fault | Tank thermistor open, sensor swap. Water still heats via boost. |
| Reclaim | Hot water | E5 | High-pressure fault (CO2) | STOP unit. Refrigerant charge / heat-exchanger issue. Warranty service. |
| Reclaim | Hot water | E6 | Low-pressure fault (CO2) | STOP unit. Likely refrigerant leak, Reclaim tech required. |
| Reclaim | Hot water | E7 | Compressor overload | STOP unit. Compressor at risk, book warranty service. |
| Reclaim | Hot water | F1 | Comms error tank ↔ heat pump | Check the comms wire between the outdoor heat pump and the tank controller. |
| iStore | Hot water | E1 | Ambient temp sensor fault | Sensor open-circuit. Book service, water will still heat on boost element. |
| iStore | Hot water | E2 | Evaporator sensor fault | Sensor swap by installer. |
| iStore | Hot water | E3 | Condenser sensor fault | Sensor open, service call. |
| iStore | Hot water | E4 | Tank sensor fault | Tank thermistor fault, sensor swap. |
| iStore | Hot water | E5 | Compressor high pressure | STOP unit. Likely blocked evaporator airflow. Clean coil. |
| iStore | Hot water | E7 | Anti-freeze protection triggered | Very cold ambient, normal in winter. If persistent, book service. |
| iStore | Hot water | E8 | Compressor drive fault | STOP unit. Inverter drive fault, warranty repair. |
| Thermann | Hot water | E1 | Water temp sensor fault (integrated HP) | Sensor open, Thermann service call. |
| Thermann | Hot water | E2 | Ambient sensor fault | Sensor open, swap by installer. |
| Thermann | Hot water | E5 | Compressor overload | STOP unit. Book warranty service. |
| Thermann | Hot water | F1 | Comms error (integrated HP) | Check internal comms wire between board and controller. |
| Thermann | Hot water | 12 | G-series continuous flow, ignition failure | Check gas supply on. If OK, needs a licensed gas fitter. |
| Thermann | Hot water | 11 | G-series, no ignition detected | Gas valve or igniter fault. Book a gas fitter. |
| Braemar | Gas heater | 23 | Overheat lockout | Blocked filter or return-air path. Clean filter and reset. |
| Braemar | Gas heater | 27 | Ignition failure (no flame sensed) | Check gas is on. If OK, needs a licensed gas fitter to inspect igniter + flame sensor. |
| Braemar | Gas heater | 42 | Fan proving switch fault | Fan not detected running. Book gas heater service. |
| Braemar | Gas heater | 51 | Wall-controller comms lost | Check the low-voltage comms wire between controller and unit. |
| Braemar | Gas heater | 58 | Zone motor / damper fault | One zone motor stuck, book service to swap the damper motor. |
| Bonaire | Evap cooler | E01 | Water pump fault (evap) | Check evap water supply on. If OK, pump swap needed. |
| Bonaire | Evap cooler | E02 | Water level fault (evap) | Water inlet blocked or float stuck. Clean the reservoir. |
| Bonaire | Evap cooler | E04 | Fan motor fault | Motor seized or capacitor gone. Book service. |
| Bonaire | Evap cooler | E05 | Ambient temp sensor fault | Outdoor sensor open, sensor swap by installer. |
| Bonaire | Evap cooler | E12 | Comms error (integrated system) | Check comms wire between wall controller and unit. |
| Sanden | Hot water | F1 | Comms error tank ↔ heat pump | Check the comms cable between heat pump and tank controller. |
| Sanden | Hot water | F2 | Tank temp sensor fault | Tank thermistor swap, service call. |
| Sanden | Hot water | F3 | Ambient sensor fault | Outdoor sensor open. Service call. |
| Sanden | Hot water | F5 | High-pressure protection (CO₂) | STOP unit. Refrigerant issue. Warranty tech required. |
| Sanden | Hot water | F7 | Compressor overload | STOP unit. Book warranty service. |
| Rheem | Hot water | 1 | Water temp sensor fault | Sensor open, book service. Element still heats but at fixed temp. |
| Rheem | Hot water | 12 | Ignition failure (gas storage) | Check gas supply. If OK, needs a gas fitter, igniter or valve fault. |
| Rheem | Hot water | 14 | Blocked flue | STOP unit. Flue restriction / no draft. Gas fitter required immediately. |
| Rinnai | Hot water | 11 | No ignition on gas continuous flow | Check the gas isolation valve is open. If OK, gas fitter needed. |
| Rinnai | Hot water | 12 | Flame failure (drops out mid-shower) | Gas pressure low or igniter dirty. Book Rinnai service. |
| Rinnai | Hot water | 14 | Thermal fuse activated (overtemp) | STOP unit. Overheat safety triggered, book service before use. |
| Rinnai | Hot water | 16 | High temp warning | Temperature setting or thermistor issue. Check controller setpoint first. |
| Rinnai | Hot water | 61 | Fan motor fault | Fan not spinning. Book service. |
| Mitsubishi Electric | Air conditioner | P7 | System error / multi-head miswire | Indoor unit address conflict on multi-head. Requires MXZ config check. |
| Mitsubishi Electric | Air conditioner | U8 | Outdoor DC voltage abnormal | STOP unit. Power supply or inverter drive fault, warranty service. |
| Daikin | Air conditioner | H9 | Outdoor ambient sensor fault | Sensor open, swap fix. |
| Daikin | Air conditioner | J3 | Discharge pipe thermistor fault | Sensor swap by installer. |
| Daikin | Air conditioner | P4 | Heat sink temperature abnormal | STOP unit. Inverter overheat. Warranty service. |
Code not in the list?
We service every major brand. Send us the code, the brand and (ideally) a photo of the wall controller. We’ll come back with what it means and a fixed-price service quote.
Know the code. Now, is it worth fixing?
Past about ten years on hot water and gas heating, and twelve on aircon, a significant repair usually costs more per remaining year than a replacement does — and it’s the same point at which the VEU rebate is worth the most. If yours is young and the fault is a component, we’ll fix it and say so.
Repair or replace? The 10-year rule →Broken unit worth repairing, or time to replace?
We give the honest answer, sometimes a new install with the VEU rebate is cheaper than the repair.