Search or filter by brand to decode what a flashing error on your split, ducted or multi-head aircon actually means. Each entry lists the likely cause and the first thing to check before booking a service call. Covers every major brand we install plus the ones we don’t.

BrandSystemCodeLikely meaningFirst check
Mitsubishi ElectricAir conditionerP1Indoor room-thermistor faultIndoor unit thermistor loose or failed, needs a service call.
Mitsubishi ElectricAir conditionerP2Indoor pipe-thermistor faultPipe sensor open-circuit, usually a swap-out fix.
Mitsubishi ElectricAir conditionerP4Drain sensor faultCheck the condensate drain pan isn't clogged; sensor may need replacing.
Mitsubishi ElectricAir conditionerP5Drain pump faultCondensate pump seized or blocked, clear the drain line and re-test.
Mitsubishi ElectricAir conditionerP6Coil frost / overheat protectionFilter blocked or airflow restricted. Clean filters + check outdoor coil.
Mitsubishi ElectricAir conditionerP8Pipe temperature abnormalLow refrigerant charge or restriction. Needs an ARC-licensed tech.
Mitsubishi ElectricAir conditionerE0Remote-control transmission errorWired controller comms drop, check controller wire terminations.
Mitsubishi ElectricAir conditionerE6Indoor / outdoor comms failureCheck the S1-S2-S3 comms wire between indoor & outdoor units.
Mitsubishi ElectricAir conditionerE9Indoor / outdoor comms error (variant)Same as E6, comms cable, check for damage or loose terminals.
Mitsubishi ElectricAir conditionerU2Compressor overheat / oil shortageSTOP using the unit. Compressor at risk, book a warranty service call.
Mitsubishi ElectricAir conditionerU4Outdoor thermistor open-circuitOutdoor coil or discharge sensor faulty. Tech required.
DaikinAir conditionerA1Indoor PCB defectIndoor board fault, power-cycle the unit first, then service if it returns.
DaikinAir conditionerA5High-pressure control / freeze-up protectionFilter dirty or outdoor coil blocked. Clean both, re-test.
DaikinAir conditionerA6Indoor fan motor faultFan motor stalled or capacitor failed. Service call.
DaikinAir conditionerC4Indoor heat-exchanger thermistor faultSensor open-circuit, swap-out fix.
DaikinAir conditionerC9Indoor air suction thermistor faultRoom-temp sensor failed. Service call.
DaikinAir conditionerE1Outdoor PCB defectOutdoor board fault. Power-cycle first, then book service.
DaikinAir conditionerE5OL activated (compressor overload)STOP unit. Compressor overload, likely refrigerant charge or fan issue.
DaikinAir conditionerE6Compressor lock / start failureSTOP unit. Compressor won't spin up. Warranty / service.
DaikinAir conditionerE7Outdoor fan motor lockCheck for debris jamming the outdoor fan. If clear, motor swap.
DaikinAir conditionerF3Discharge-pipe temperature too highLow refrigerant charge or blocked outdoor coil. ARC tech needed.
DaikinAir conditionerL5Inverter compressor abnormalSTOP unit. Inverter fault, warranty repair.
DaikinAir conditionerU0Refrigerant shortageRefrigerant low, check for leak, book an ARC-licensed tech.
DaikinAir conditionerU4Indoor / outdoor comms errorCheck the F1-F2 comms wire, loose terminal or damaged cable.
FujitsuAir conditionerE:EERoom-temp thermistor faultThermistor open, sensor swap.
FujitsuAir conditionerE:11Comms error indoor ↔ outdoorComms wire fault. Check terminals both ends.
FujitsuAir conditionerE:12Outdoor comms not respondingOutdoor board or power supply, book service.
FujitsuAir conditionerE:14Signal transmission error (wired remote)Wired controller, check the H1-H2 line terminations.
FujitsuAir conditionerOP:00Outdoor high-pressure protectionAirflow blocked at outdoor unit. Clear obstructions and re-test.
FujitsuAir conditionerOP:04Compressor discharge-temp protectionSTOP unit. Likely low charge or blocked coil.
PanasonicAir conditionerH11Indoor / outdoor comms failureComms cable fault. Check terminals.
PanasonicAir conditionerH15Compressor sensor errorSensor failed, service call.
PanasonicAir conditionerH27Outdoor air sensor errorSensor open, swap-out fix.
PanasonicAir conditionerF91Refrigerant abnormal (leak)STOP unit. Refrigerant leak, ARC tech needed.
PanasonicAir conditionerF99Outdoor DC over-currentSTOP unit. Inverter / compressor fault. Warranty service.
LGAir conditionerCH01Indoor room-thermistor errorSensor open, swap fix.
LGAir conditionerCH02Indoor pipe sensor errorSensor open, swap fix.
LGAir conditionerCH05Indoor / outdoor comms errorComms cable, check terminals both ends.
LGAir conditionerCH21IPM fault (inverter power module)STOP unit. Inverter power stage, book warranty service.
KadenAir conditionerE1Indoor & outdoor comms errorCheck comms cable connection between heads.
KadenAir conditionerE2Room temp sensor faultSensor open, sensor swap by installer.
KadenAir conditionerE5Overcurrent protectionAirflow blocked or refrigerant charge low. Service call.
KadenAir conditionerF1Outdoor unit sensor faultOutdoor sensor swap, book service.
KadenAir conditionerF3Compressor discharge temp too highSTOP unit. Likely low charge. ARC tech required.
BrivisGas heaterh01 30Fan limp mode, fan speed sensor signal invalidUnit runs at safe speed. Book gas heater service, main fan sensor or motor.
BrivisGas heaterh01 31Flame roll-out during ignition (auto restart)Unit will attempt to restart. If it persists, book service, roll-out sensor / burner alignment.
BrivisGas heaterh01 32Data error, parameters reset to defaultController memory fault. Book service to re-commission the unit.
BrivisGas heaterh01 33Modulating gas valve, open circuit on coilModulation coil fault. Needs a gas fitter service call.
BrivisGas heaterh01 35Supply-air thermistor fault (open / short)Sensor swap by installer, no heat until fixed.
BrivisGas heaterh01 36Bad supply-air thermistor locationThermistor not reaching setpoint in time, indicates blocked ducts or sensor moved. Book service.
BrivisGas heaterh01 37Speed sensor error, unit in safe modeMain-fan speed signal wrong. May lockout if persistent. Book service.
BrivisGas heaterh01 40Return-air overheat, flue-fan overheat switch openReturn-air blockage or fan issue. Clean return-air filter first, then service.
BrivisGas heaterh01 41Supply-air overheat switch trippedBlocked supply ducts / grille. Check no vents shut. Service if it persists.
BrivisGas heaterh01 42Supply-air thermistor temp exceeded overheat thresholdDuct blockage forcing overheat. Open all vents, clean filter, book service if persists.
BrivisGas heaterh01 43Overheat cool-down in progressUnit cooling itself down safely. Wait 5 min. If it recurs, service.
BrivisGas heaterh01 44Flame roll-out detected during ignitionRoll-out sensor triggered. Book gas fitter, burner or heat exchanger issue.
BrivisGas heaterh01 45Low 24V AC supply voltagePower supply issue on the low-voltage transformer. Service call.
BrivisGas heaterh01 46No flame on ignition attemptCheck gas isolation valve is on. If good, book a gas fitter, igniter, gas pressure, or flame rod.
BrivisGas heaterh01 47Unstable flame, dropped during validationGas pressure or flame rod issue. Book a gas fitter.
BrivisGas heaterh01 48Pressure loss, combustion chamber switch opened mid-cycleFlue restriction or fan issue. Book service, check flue is clear.
BrivisGas heaterh01 49Flame lost during heating cycleGas supply interruption or flame sensor issue. Book gas fitter.
BrivisGas heaterh01 50Ignition lockout, max ignition attempts exceededSTOP unit. Power cycle at the wall control to reset. If it re-locks, gas fitter required.
BrivisGas heaterh01 51Roll-out signal with no gas active (sensing circuit fault)Roll-out sensor circuit fault. Book service.
BrivisGas heaterh01 52Flame signal detected with no gas, flame sensing circuit faultFlame rod / control board fault. Book service.
BrivisGas heaterh01 53Overheat lockoutSTOP unit. Overheat safety triggered multiple times. Gas fitter required before use.
BrivisGas heaterh01 54Roll-out lockout, max roll-out events during heat cycleSTOP unit. Repeated roll-out, burner / heat exchanger inspection required.
BrivisGas heaterh01 55Flame validation lockout, flame lost repeatedly at validate stepSTOP unit. Book gas fitter, flame or gas supply issue.
BrivisGas heaterh01 56Pressure switch stuck open, flue fan on but no pressurePressure switch or tube blocked. Book service.
BrivisGas heaterh01 57Pressure switch stuck closed, flue fan off but pressure detectedPressure switch stuck. Book service.
BrivisGas heaterh01 58Pressure switch fail, max pressure-loss events exceededSTOP unit. Flue / pressure switch fault. Book service.
BrivisGas heaterh01 59Cross-check comms error between primary and secondary MCUControl board comms fault. Board-level service required.
BrivisGas heaterh01 60Motor open circuit, no zero-cross detect signalFan motor open circuit, book service. Motor swap likely.
BrivisGas heaterh01 61Primary valve stuck off, relay contact not closingGas valve relay fault. Book gas fitter.
BrivisGas heaterh01 62Primary valve stuck on, relay contact weldedSTOP unit. Gas valve relay stuck. Gas fitter needed immediately.
BrivisGas heaterh01 63Primary valve fail, relay not closing during heatingSTOP unit. Gas valve fault. Book gas fitter.
BrivisGas heaterh01 64Modulating valve overcurrent (>150 mA)Modulation coil short. Book service.
BrivisGas heaterh01 65Motor lockout, fan limp + open circuit or overheat comboSTOP unit. Multiple fan faults combined. Book service.
BrivisGas heaterh01 66Secondary valve stuck offSecond gas valve relay fault. Gas fitter.
BrivisGas heaterh01 67Secondary valve stuck onSTOP unit. Gas valve stuck. Gas fitter needed immediately.
BrivisGas heaterh01 68Secondary valve fail during heatingSTOP unit. Gas fitter required.
BrivisGas heaterh01 69Fuse blown, 24V AC voltage lost2A fuse on the control board is open. Service call to replace + diagnose why it blew.
BrivisGas heaterh01 70Remote MCU shutdown failControl-board fault. Board-level service.
BrivisGas heaterh01 71Remote MCU state mismatchControl-board fault. Board-level service.
BrivisGas heaterh01 72Ambiguous fault, unattributed shutdownUndiagnosed shutdown. Book service to read secondary log.
BrivisGas heaterh01 73Remote MCU next-state mismatchControl-board firmware or hardware fault. Book service.
BrivisGas heaterh01 74Remote MCU lockout (secondary board locked)STOP unit. Board-level service required.
BrivisGas heaterh01 75AC input scan fault, 24V input stuck highInput scanning circuit fault. Board-level service.
BrivisGas heaterh01 76Lockout storage fault, non-volatile memory access failureControl board's ability to store lockouts compromised. Book service.
BrivisGas heaterh01 77Remote MCU IO mismatchIO state mismatch between board MCUs. Book service.
BrivisGas heaterh01 79A/D converter reference voltage check failedBoard-level analog fault. Service.
BrivisGas heaterh01 80Flame sense fault, measured voltage out of rangeFlame rod or sensing circuit fault. Book gas fitter.
BrivisGas heaterh01 81Roll-out sense fault, sensor voltage out of rangeRoll-out sensor circuit fault. Book service.
BrivisGas heaterh01 82System timing fault, MCU timing vs 50 Hz mismatchControl-board timing fault. Board-level service.
BrivisGas heaterh01 83System execution fault, internal MCU errorControl-board firmware fault. Board-level service.
BrivisGas heaterh01 84Control board lockout (system lockout initiated)STOP unit. Board-level service required.
BrivisGas heaterh01 85Control board lockout (system lockout initiated)STOP unit. Board-level service required.
BrivisGas heaterh01 86Control board lockout (system lockout initiated)STOP unit. Board-level service required.
BrivisGas heaterh01 87Cross-check comms fault, no MCU comms >10 sControl-board comms failure. Board-level service.
BrivisGas heaterh01 88Control board lockout (system lockout initiated)STOP unit. Board-level service required.
BrivisGas heaterh01 89MCU non-volatile storage test code (not seen in normal use)Diagnostic-only code, service tech will interpret. If it appears on normal operation, book service.
ReclaimHot waterE1Ambient temp sensor faultOutdoor sensor open-circuit. Book a Reclaim-accredited service tech.
ReclaimHot waterE2Evaporator temp sensor faultEvaporator sensor fault, swap-out fix by a tech.
ReclaimHot waterE3Discharge / suction sensor faultSensor swap by an ARC-licensed tech.
ReclaimHot waterE4Tank temp sensor faultTank thermistor open, sensor swap. Water still heats via boost.
ReclaimHot waterE5High-pressure fault (CO2)STOP unit. Refrigerant charge / heat-exchanger issue. Warranty service.
ReclaimHot waterE6Low-pressure fault (CO2)STOP unit. Likely refrigerant leak, Reclaim tech required.
ReclaimHot waterE7Compressor overloadSTOP unit. Compressor at risk, book warranty service.
ReclaimHot waterF1Comms error tank ↔ heat pumpCheck the comms wire between the outdoor heat pump and the tank controller.
iStoreHot waterE1Ambient temp sensor faultSensor open-circuit. Book service, water will still heat on boost element.
iStoreHot waterE2Evaporator sensor faultSensor swap by installer.
iStoreHot waterE3Condenser sensor faultSensor open, service call.
iStoreHot waterE4Tank sensor faultTank thermistor fault, sensor swap.
iStoreHot waterE5Compressor high pressureSTOP unit. Likely blocked evaporator airflow. Clean coil.
iStoreHot waterE7Anti-freeze protection triggeredVery cold ambient, normal in winter. If persistent, book service.
iStoreHot waterE8Compressor drive faultSTOP unit. Inverter drive fault, warranty repair.
ThermannHot waterE1Water temp sensor fault (integrated HP)Sensor open, Thermann service call.
ThermannHot waterE2Ambient sensor faultSensor open, swap by installer.
ThermannHot waterE5Compressor overloadSTOP unit. Book warranty service.
ThermannHot waterF1Comms error (integrated HP)Check internal comms wire between board and controller.
ThermannHot water12G-series continuous flow, ignition failureCheck gas supply on. If OK, needs a licensed gas fitter.
ThermannHot water11G-series, no ignition detectedGas valve or igniter fault. Book a gas fitter.
BraemarGas heater23Overheat lockoutBlocked filter or return-air path. Clean filter and reset.
BraemarGas heater27Ignition failure (no flame sensed)Check gas is on. If OK, needs a licensed gas fitter to inspect igniter + flame sensor.
BraemarGas heater42Fan proving switch faultFan not detected running. Book gas heater service.
BraemarGas heater51Wall-controller comms lostCheck the low-voltage comms wire between controller and unit.
BraemarGas heater58Zone motor / damper faultOne zone motor stuck, book service to swap the damper motor.
BonaireEvap coolerE01Water pump fault (evap)Check evap water supply on. If OK, pump swap needed.
BonaireEvap coolerE02Water level fault (evap)Water inlet blocked or float stuck. Clean the reservoir.
BonaireEvap coolerE04Fan motor faultMotor seized or capacitor gone. Book service.
BonaireEvap coolerE05Ambient temp sensor faultOutdoor sensor open, sensor swap by installer.
BonaireEvap coolerE12Comms error (integrated system)Check comms wire between wall controller and unit.
SandenHot waterF1Comms error tank ↔ heat pumpCheck the comms cable between heat pump and tank controller.
SandenHot waterF2Tank temp sensor faultTank thermistor swap, service call.
SandenHot waterF3Ambient sensor faultOutdoor sensor open. Service call.
SandenHot waterF5High-pressure protection (CO₂)STOP unit. Refrigerant issue. Warranty tech required.
SandenHot waterF7Compressor overloadSTOP unit. Book warranty service.
RheemHot water1Water temp sensor faultSensor open, book service. Element still heats but at fixed temp.
RheemHot water12Ignition failure (gas storage)Check gas supply. If OK, needs a gas fitter, igniter or valve fault.
RheemHot water14Blocked flueSTOP unit. Flue restriction / no draft. Gas fitter required immediately.
RinnaiHot water11No ignition on gas continuous flowCheck the gas isolation valve is open. If OK, gas fitter needed.
RinnaiHot water12Flame failure (drops out mid-shower)Gas pressure low or igniter dirty. Book Rinnai service.
RinnaiHot water14Thermal fuse activated (overtemp)STOP unit. Overheat safety triggered, book service before use.
RinnaiHot water16High temp warningTemperature setting or thermistor issue. Check controller setpoint first.
RinnaiHot water61Fan motor faultFan not spinning. Book service.
Mitsubishi ElectricAir conditionerP7System error / multi-head miswireIndoor unit address conflict on multi-head. Requires MXZ config check.
Mitsubishi ElectricAir conditionerU8Outdoor DC voltage abnormalSTOP unit. Power supply or inverter drive fault, warranty service.
DaikinAir conditionerH9Outdoor ambient sensor faultSensor open, swap fix.
DaikinAir conditionerJ3Discharge pipe thermistor faultSensor swap by installer.
DaikinAir conditionerP4Heat sink temperature abnormalSTOP unit. Inverter overheat. Warranty service.
Showing 149 of 149 codes

Code not in the list?

We service every major brand. Send us the code, the brand and (ideally) a photo of the wall controller. We’ll come back with what it means and a fixed-price service quote.

Know the code. Now, is it worth fixing?